Description
- Technical data AP-120
- Recommended area 140 m²
- Air volume 1,200 m³/h
- Operating voltage 230 V
- Frequency 50 Hz
- Connection cable 2 m
- Connector plug
- Motor EC motor (electronic control)
- Dimensions 1,375 x 700 x 610 mm
- Weight 82 kg
- Operating temperature 5 °C – 40 °C
- Relative humidity < 80 %
- Operation Guard switch on rear side
- Pre-filter yes
- HEPA-filter H14 Medical
- Dust class H14 – according to DIN EN 1822 (ISO 45H fi lter ISO 29463)
- H – according to DIN EN 60335-2-69
- F7 – according to DIN EN 779:2002
- Activated carbon filter yes, honeycomb
- UV lamp yes (254 nm)
- Photocatalyst yes (TiO₂)
- Plasma yes
- Air duct Inlet rear / outlet front
- Change interval
- UV lamp
- approx. 8000 h
- Test reports CE, ROHS, EMC, official biologic and filter function report of GDIM
- Viruses / Bacteria tested (Details see Report) Viruses H1N1, H3N2 and Bacteria
- Filter test PM2.5 / PM0.3
- Housing Flight case with rollers, handles and edge protecti on Volume (measured, 1m)
- Level L: 35 dB
- Level M: 43 dB
- Level H: 59 dB
- Volume (measured, 3m)
- Level L: 34 dB
- Level M: 39 dB
- Level H: 53 dB
- Air volume – motor speed
- Level L: 805 m³ – 435 U/min
- Level M: 972 m³ – 546 U/min
- Level H: 1290 m³ – 724 U/min
- Power consumption:
- UV lamp off :
- Level L: 40,5 W
- Level M: 61,8 W
- Level H: 105 W
- UV lamp on: + 40 W
- Type I